Auxiliary Gutter Sizing
2 i have 4ea 4 pvc conduits leaving the disconnect carrying 4ea 500mcm 1ea 250mcm traveling approximately 60 to the.
Auxiliary gutter sizing. Adding additional downspouts will require less gutter and downspout volume resulting in smaller gutters downspouts. 6 inch 7 960 square feet. The conductors including splices and taps shall not fill the wireway to more than 75 percent of its area at the point of a splice or tap. Auxiliary gutter the foreman on the job has instructed me to install an aux.
They can be 4 5 or 6 inches. Sizing a gutter for the proper fit is relatively easy. The capacities of bars cannot exceed 1 55 a per square millimeter 1000 a per square inch for copper and 1 09 a per mm2 700 a per square inch for aluminum. Gutters come in different sizes.
Table 1 wireway size cross section in2 max. 5 inch 5 520 square feet. I get a lot of calls to make sure that the gutter that they are using is up to code. Multiply the drainage area by the roof pitch factor and rainfall intensity to find out the adjusted square footage.
Then use the chart below to see what size gutter you need. Please lower the maximum spacing between downspouts to see this effect. Sizing calculator wireway selection 4 x4 6 x6 8 x8 4 o uses splices and taps splices and taps are permitted within a wireway provided they are accessible. Gutter above the panel power wall to combine conduits and circuits for the branch distribution.
This auxiliary gutter used as a pull box is 5ft long 14inches deep by 14inches in height. We are allowed by code to fill a gutter to 20. If a roof s various drainage areas call for different size gutters go for the biggest one k style. The gutter is 12x12x60 with 33 3 4 17 1 4 1 1 4 1 2 conduits out of the top.
It is easy to see that you can vary gutter size downspout size and downspout spacing to properly size a gutter downspout system. There are two 4inch conduits feeding the bottom of the gutter with 4x600mcm conductors in parallel in each which pass straight through to the two 4inch nipples which connect to the bottom of the meter assembly feeding the 800 amp breaker. Of its interior cross sectional area 366 22 a b this is for both sheet metal and nonmetallic gutters. When there are not more than 30 current carrying conductors the derating factors for ampacities do not have to be applied.
3 these conduits and. Downspouts also come in different sizes such as 2 3 inches and 3 4 inches in size. Sizing an auxilliary gutter 1 i have a 1200a 208v 3p 4w fused disconnect and meter for a restaurant in the electrical room in the basement of a. By reducing the downspout spacing to perhaps 35lf you could use a 6 gutter with 9 4 x6 downspouts in lieu of an 8 system.
Figuring the 20 is easy for example.