Attic Hatch Weather Stripping
A 5 4 1 2 1 and 2 air leakage through air barrier system astme283 air leakage single panel csa a440 test rating a1 double panel csa a440 test rating a2.
Attic hatch weather stripping. Whole house fan shutter cover. The md building products 1 in. To ensure an airtight seal the foam weather stripping should be attached to the top of the box being careful not stretch it out. If your hatch rests directly on the moldings add 2 1 2 inch wide stops around the opening.
Sealing the attic hatch or door finish up by sealing the access hatch with self sticking weather stripping. To determine the amount of weatherstripping needed measure the perimeters of all areas to be weather stripped and then add 10 percent to allow for waste. Before installation the surface area must. Align the end of the weather stripping with one corner of the scuttle hole with.
Remove your existing attic hatch and measure its size. Every attic access hatch needs weatherstripping. Attic tent 20 battic door 9 draftmaster 6 insul door 1 seal n shield 6 therma dome 1 type. The stops provide a wider surface for attaching the weatherstrip and a space to mount hook and eye fasteners.
If the attic hatch rests on the molding you should add 2 1 2 inch stops around the entire opening. Use the foam compatible glue to fasten the insulation to the back of the hatch. 9 19 2 1 2 no dimensions less than 545 mm attic hatch inc. Pull 12 inches of backing paper from the adhesive side of a roll of self adhesive 3 8 inch wide weather stripping.
Cut four pieces of polystyrene rigid insulation about 1 2 inch smaller than the dimensions of the hatch. You can also inspect the weatherstripping and molding around your attic door to see if it is damaged. This compression strip installs in a slot in the door jamb conforming to irregularities and forming a weather tight seal. Battic door deluxe ez hatch attic access door w keyed lock and handles r 50.
Vinyl clad replacement weatherstrip is designed to replace most styles of weather stripping that are factory installed. Special price 410 95. If there are indications of erratic air movement coming from your attic hatch replacement weatherstripping is necessary. Specification at 547 2 mm.
The insulation will both slow heat loss and add ballast to the hatch to improve the seal at the weatherstripping. Fine homebuilding as this thermal image shows poorly detailed attic access hatches leak a lot of heat. As you can see from this picture we attached a bolt with a hook at the end through the foam and used 2 washers a nut to make sure that it would not pull through we recommend one small washer an oversized washer to help ensure that won t happen. Some builders make their attic access hatches out of sip scraps.
Bundles 5 units 43.